Cable Gland Technical Data & Specifications
Technical specifications for our cable gland range. IP ratings, thread types, clamping ranges, material options, and temperature performance.
IP Rating Guide
IP65: dust-tight, water jet resistant. IP66: dust-tight, powerful water jet resistant. IP67: dust-tight, temporary immersion (1m, 30min). IP68: dust-tight, continuous immersion (depth/time specified). Our standard nylon glands are IP68 rated.
Thread Standards
Metric (M12-M63 per IEC 60423), PG (Pg7-Pg48 per DIN 40430), NPT (1/4 to 2), and G/PF (BSPP). We stock all common sizes with custom threads available for orders over 5,000 pcs.
Material Options
PA66 (standard, IP68), PA66 with EPDM seal (enhanced weather resistance), nickel-plated brass (EMC/EMI shielding), stainless steel 304/316 (corrosive environments, food grade, marine).
| Property | Nylon (PA66) | Nickel-Plated Brass | SS304 / SS316 |
|---|---|---|---|
| IP Rating | IP68 | IP68 | IP68 |
| Temp Range | -20C to 100C | -40C to 150C | -60C to 400C |
| Thread Types | Metric, PG | Metric, PG, NPT | Metric, NPT |
| Clamping Range | 3-44mm | 3-44mm | 6-35mm |
| EMC Capable | No | Yes (with insert) | Yes (with insert) |
| Corrosion Resistance | Good | Very Good | Excellent |
FAQ
How do I select the correct cable gland size?
Measure the outer diameter of your cable. The gland clamping range must cover your cable OD. See our Cable Gland Selection Guide for step-by-step instructions.
Do you provide 3D CAD models?
Yes. STEP and IGES files are available for all standard gland sizes. Contact us with your required sizes and thread types.